S9200U1000 Honeywell Universal Hot Surface Igntion Control

S9200U1000 Honeywell Universal Hot Surface Igntion Control
The S9200U1000 can be used with conventional thermostats as well as the EnviraCOM™ enabled VisionPRO IAQ and FocusPRO. The S9200U1000 Universal Integrated Furnace Control is intended for residential natural or liquid propane fueled furnaces only. The S9200U1000 EnvriaCOM™ communications capability allows its use in twinning applications and enables communication with local and remote diagnostic devices such as the QuickLook hand held device (QuickLook™ 72), EnviraLNK® web-based application and the W8735D Telephone Access Module (TAM).


Features


• Main burner ignition using a 120V hot surface igniter.
• Flame rectification circuit to monitor flame presence.
• Monitoring of system pressure switch, high temperature limit, and rollout functions.
• Appliance operation/safety requirements controlled via microprocessor.
• Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM™ thermostat.
• LED system status, performance and diagnostic indication.
• Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances.
• Twinning capability
• EnviraCOM™ communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control.

Product Specifications Back To Top

Description Universal single stage heating & cooling
Line Voltage 120Vac (97-132 Vac)
Low Voltage 24V (18-30Vac)
Frequency 60 Hz
Operating Temperature (F) -40 F to +175 F
Operating Temperature (C) -40 C to +79 C
Operating Humidity Range (% RH) 0% to 95% non-condensing
Igniter Current 1.0A resistive @ 95Vac output
Thermostat Anticipator Setting (Stage 1 only) 100mA
PrePurge 30 seconds
HSI Warmup Time 17/27 or 30/30 seconds
Trial For Ignition 4, 6, or 8 seconds
PostPurge 15 seconds
Interpurge 60 secods
Ignition Trials Three, two tries if flame is not sensed
Flame Failure Response Time 2 Seconds max @ 1µA
Number of LEDs 3
Heat On Fan Delay 30 or 60 seconds
Heat Off Fan Delay 60, 90, 120, or 180 Seconds
Cool Fan On Delay 5 seconds
Cool Fan Off Delay 0 or 60 seconds
Gas Control Used With Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
Cooling Contactor Used With Any 24Vac contactor rated at 1.0A or less
Induced Draft Blower Load 2.2FLA / 25LRA max @120Vac
Ciculator Load 14.5FLA / 25LRA max @120Vac
Type of Fan Used With Standard Induction-Type Circulating Fan




S9200U1000 Universal Integrated Furnace Control Cross-Reference Guide
Manufacturer/ Model Number


CARRIER WIRING HARNESS USED
903106- 50024568: Main Connector & 50024565 Inducer & HSI Connector

CAR33101972200 -------------50024568: Main Connector & 50024566 Inducer & HSI Connector
CAR03101973000
CAR50A55843

CARB1809913S---------------- 50026393: Main Connector & 50026446 Inducer & HSI Connector

GOODMAN WIRING HARNESS USED
1809913------------------------ 50026393: Main Connector & 50026446 Inducer & HSI Connector
18099-13S
B180996
B1809906
B18099-6
B18099-06
B1809908
B18099-08
B1809910
B18099-10
B18009910
B180099-10
B1809913
B18099-13
B1809913S
B18099-13S
B18009913
B180099-13
PSIB18099-13PSI------------------------ No wiring harness required

ICM CONTROLS WIRING HARNESS USED
ICM280------------------------- 50026393: Main Connector & 50026446 Inducer & HSI Connector

LENNOX WIRING HARNESS USED
G951ADB1401----------------- 50024568: Main Connector & 50024566 Inducer & HSI Connector
G951ADB1401C
G951ADB-1401C
G951ADB1402
G951ADB-1402
G951AEB-1403

NORDYNE WIRING HARNESS USED
624557------------------------- 50024568: Main Connector & 50024565 Inducer & HSI Connector
6245570
624557-0
624564
6245640
624591
624591A
624591-A
624591-B
624591-C
624591-D
624628
624628-0
6246310
624631-0
624631A
624631-A
624631-B
710128A
902378
902696
903106
PSI903106PSI-------------------------- No wiring harness required

YORK WIRING HARNESS USED
3100662000-------------------- 50024568: Main Connector & 50024566 Inducer & HSI Connector
031-00662-000
031-00662-700
031-01140-000
031-01140-001
31011140002
031-01140-002
031-01140-701
031-01140-702
031.01234.000
031-01234-700
031-01235-700
031-01250-000
310126700
031-01267-000
031-01267-001
031-01267-001A
031-01284-000
3101933000
031-01933-000
031-01972-000
031-01973-000
031-02166-000
33101933000
331-01933-000
031-01972-000
031-01973-000
031-02166-000
33101933000
331-01933-000
331-01972-200
43101972100
431-01972-100
P03101267001
P031-01267-001
P031-01267-001
PSI031011400-00
PTH031011400-00

RHEEM / RUUD WIRING HARNESS USED
62-24268-01------------------- 50024568: Main Connector & 50024566 Inducer & HSI Connector
62-24268-02
62-24268-03

TEXAS INSTRUMENTS WIRING HARNESS USED
6DT-1--------------------------- 50024568: Main Connector & 50024566 Inducer & HSI Connector
6DT-2
61F3
41F-5--------------------------- 50026393: Main Connector & 50026446 Inducer & HSI Connector

WHITE-RODGERS WIRING HARNESS USED
50A50-209--------------------- 50024568: Main Connector & 50024566 Inducer & HSI Connector
50A50-230
50A55-241
50T35730---------------------- 50026393: Main Connector & 50026446 Inducer & HSI Connector
50T35-730
50T35743
50T35-743
50A55-843---------------------- No wiring harness required
50A55-120
50A55-143
50A55-285
50A55-286
50A55-288
50A55-438
50A55-(474-571)
50A50-143
50A50-285
50A50-286
50A50-438

UTEC WIRING HARNESS USED
1012-925A--------------------- 50024568: Main Connector & 50024566 Inducer & HSI Connector
1012-925B
1012-925C
1012-955A--------------------- 50024568: Main Connector & 50024565 Inducer & HSI Connector
1012955A
1012-83-9651B---------------- 50024568: Main Connector & 50024566 Inducer & HSI Connector
1012-930----------------------- 50026393: Main Connector & 50026446 Inducer & HSI Connector
1012933D
1012-933D
1012-83-9336AHSC1
1012-83-9337A


Details
SKU HONS9200U1000
Weight 0.01 lbs
 
Our price: $98.55
Options
Quantity
: *
: *
: *